"state_well_number","group_number","remarks_1","remarks_2" 2762607,1,"Abandoned PS well. ", 2762608,1,"MP= +2.50 feet ", 2763402,1,"Oil Test ", 2763403,1,"Historical observation well. ","Well collapsed in at WL in 2005. " 2763506,1,"Abandoned PS well. ", 2763603,1,"Oil test. ", 2763705,1,"Unused public supply well. ","Historical observation well. " 2763712,1,"Reported yield 72 GPM in 1982. ","Cemented from 0 to 50 feet. Gravel " 2763712,2,"packed from 50 to 134 feet. ", 2763901,1,"MP= +5.00 feet ", 2763902,1,"Owner's Well #1. Pumped 25 GPM in ","1988. Gravel packed from 25 to 80 " 2763902,2,"feet. ", 2763903,1,"Owner's Well #3. Pumped 30 GPM in ","1988. Gravel packed from 25 to 80 " 2763903,2,"feet. ", 2763904,1,"Owner's Well #2. Pumped 22 GPM in ","1997. Gravel packed from 15 to 68 " 2763904,2,"feet. Cemented from 0 to 15 feet. ", 2763905,1,"Owner's Well #4. ", 2763906,1,"Owner's Well #5. ", 2763907,1,"Capped. Pumped 40 GPM in 1997. ","Gravel packed from 20 to 105 feet. " 2763907,2,"Cemented from 0 to 20 feet. ", 2763908,1,"Pumped 15 GPM in 1998. Gravel ","packed from 20 to 97 feet. Cemented" 2763908,2,"from 0 to 15 feet. ", 2764403,1,"Historical observation well. Well ","is also equipped with a windmill. " 2764502,1,"Oil test. ", 2764803,1,"Measured yield 125 GPM with 72 feet","drawdown in 1998. Gravel packed " 2764803,2,"from 20 to 150 feet. Cemented from ","0 to 18 feet. " 2857304,1,"Historical observation well. ", 2857401,1,"Historical observation well. ", 2857602,1,"Oil test ", 2857703,1,"MP= +0.50 feet ", 2857801,1,"Historical Ob. well ", 2857802,1,"well in well house close to road ","cemented from 0 to 10' " 2857903,1,"Cemented from 0 to 60 feet. Gravel ","packed from 60 to 160 feet. " 2857904,1,"Reported yield 150 GPM with 18 feet","drawdown after pumping 8 hours in " 2857904,2,"2003. Specific capacity 8.3 GPM/ft.", 2857904,3,"TR# 33881. ", 2858801,1,"Oil test. ", 4401102,1,"Historical observation well. ", 4401103,1,"Historical observation well. ", 4401205,1,"Oil test. ", 4401401,1,"Unused irrigation well. ", 4401401,2,"Historical Observation well. ", 4401602,1,"Historical observation well. ","Well 155. " 4402201,1,"Slotted steel casing from 40 to 62 ","feet. " 4402202,1,"Slotted steel casing from 40 to 62 ","feet. Historical observation well. " 4402202,2,"Destroyed irrigation well. ", 4402203,1,"Slotted steel casing from 32 to 62 ","ft. " 4402204,1,"Slotted steel casing from 32 to 62 ","ft. " 4402205,1,"Slotted steel casing from 40 to 68 ","ft. " 4402207,1,"Abandoned irrigation well. Slotted","steel casing from 40 to 70 ft. " 4402207,2,"Gravel packed. ", 4402208,1,"Unused irrigation well. ", 4402209,1,"Slotted steel casing from 40 to 71 ","feet. " 4402210,1,"Oil Test. ", 4402311,1,"Oil Test. ", 4402406,1,"Abandoned industrial well. ","Slotted steel casing. " 4402407,1,"Slotted steel casing. Reported ","yield , 98 gpm. " 4402408,1,"Slotted steel casing. Reported ","yield 72 gpm. " 4402409,1,"Slotted steel casing. Reported ","yield 40 gpm. " 4402504,1,"Well 141. ", 4402506,1,"Unused industrial well. Slotted ","steel casing. " 4402507,1,"Historical observation well. ", 4402508,1,"Slotted steel casing from 60 to 80 ","ft. Sanded from 73 to 80 ft. " 4402509,1,"Slotted steel casing from 45 to 50 ","ft. " 4402509,2,"Well 152 ", 4402602,1,"Well 147. ", 4402603,1,"Unused livestock well. Well 148. ", 4402801,1,"Formerly used as an industrial well","Plugged. " 4402902,1,"Reported yield, 3 to 5 gpm. Well ","149. " 4402903,1,"Historical observation well. ", 4409302,1,"Well #157. Historical observation ","well. " 4409401,1,"Well 244. ", 4409502,1,"Observation well. Measured yield ","8.9 GPM with 11.5 feet drawdown " 4409502,2,"after pumping 4 hours in 2001. ","Specific capacity 0.77 GPM/ft. " 4409502,3,"Aquifer test results in TWDB files.", 4409601,1,"Well 246. ", 4409601,2,"Well depth was measured as 62' in ","1967 but original well depth was " 4409601,3,"104'. ", 4409603,1,"Well 245. ", 4409803,1,"Abandoned industrial well. ", 4410104,1,"Questionable water level for 1937. ","Well 252. " 4410104,2,"Well depth was reported as 104' in ","Report M187 along with the water " 4410104,3,"level measurement from 1937, which ","is a pumping level measurement. " 4410105,1,"Well deepened in 1965. Well 253. ", 4410202,1,"Historical observation well. ", 4410205,1,"Slotted steel casing from 100 to ","110 ft. " 4410206,1,"Slotted steel casing from 75 to ","100 ft. " 4410207,1,"Perforated steel casing from 25 to ","40 ft. " 4410208,1,"Depth is reported as both 40 and 60","feet on different paperwork. Note " 4410208,2,"on water quality field sheet from ","when water level deeper than depth " 4410208,3,"was taken says sure of both locatio","n and water level. Deleted well " 4410208,4,"depth. ", 4410209,1,"Slotted steel casing from 122 to ","212 ft. " 4410210,1,"Slotted steel casing from 122 to ","212 ft. cemented to 212 ft. " 4410210,2,"Reported yield, 105 gpm. ", 4410303,1,"Reported yield, 25 to 30 gpm. ", 4410401,1,"Slotted steel casing from 96 to 186","ft. Gravel packed to 186 ft. " 4410401,2,"Reported yield, 68 gpm. ", 4410402,1,"Unused livestock well. ", 4410404,1,"Perforated casing to 168 ft. ","Unused irrigation well. " 4410407,1,"Unused irrigation well. ", 4410408,1,"""Peck's Spring."" ", 4410409,1,"Slotted steel casing from 103 to ","193 ft. Reported yield, 156 gpm. " 4410502,1,"Test hole. ", 4410503,1,"Reported yield, 200 gpm. ", 4410507,1,"Slotted steel casing from 155 to ","242 ft. Reported yield, 69 gpm. " 4410605,1,"Unused industrial well. ", 4410608,1,"Well 254. ", 4410609,1,"Perforated casing from 80 to 110 ","ft. Reported yield, 250 gpm. " 4410610,1,"Perforated casing from 80 to 110 ","ft. " 4410611,1,"Perforated casing from 80 to 110 ft",". Reported yield, 150 gpm. " 4410702,1,"Shackleford Supply Unit, water ","supply well 22. Slotted casing " 4410702,2,"from 195 to 250 ft. Reported ","yield, 70 gpm. " 4410703,1,"Shackleford Supply Unit, water ","supply well 26. Slotted casing " 4410703,2,"from 178 to 222 ft. Reported yield","90 gpm. " 4410901,1,"Well 256 deepened by Wheeler in ","1940. " 4410907,1,"Abandoned industrial well. ", 4417304,1,"Shackleford Supply Unit, water ","supply well 10. Slotted casing " 4417304,2,"from 168 to 268 ft. Reported yield","72 gpm. " 4417305,1,"Shackleford Supply Unit, water ","supply well 12. Slotted casing " 4417305,2,"from 156 to 262 ft. Reported yield","75 gpm. " 4417306,1,"Shackleford Supply Unit, water ","supply well 13. Slotted casing " 4417306,2,"from 140 to 265 ft. Reported yield","100 gpm. " 4417401,1,"Perf. casing from 60 to 100 ft. ","Reported yield 36 gpm. " 4417402,1,"Perforated casing from 100 to 160 ","ft. Well 274. " 4417403,1,"Unused livestock well. Well 276. ", 4417405,1,"Perforated casing from 108 t 168 ","ft. " 4417601,1,"Unused irrigation well. Reported ","yield 35 gpm. " 4417602,1,"Reported yield 120 gpm. Pumping ","water level in 1966. " 4417603,1,"Reported yield, 70 gpm. ", 4417604,1,"Reported yield 90 gpm. ", 4417608,1,"Reported yield 40 gpm. ", 4417609,1,"Unused irrigation well. Reported ","yield 65 gpm. " 4417610,1,"Reported yield 70 gpm. ", 4417611,1,"Unused irrigation well. Reported ","yield , 70 gpm. " 4417612,1,"Unused irrigation well. Perforated","casing. Reported yield, 70 gpm. " 4417613,1,"Unused irrigation well. Slotted ","casing. Reported yield 50 gpm. " 4417614,1,"Unused irrigation well. Reported ","yield, 55 gpm. " 4417615,1,"Unused irrigation well. Reported ","yield 60 gpm. " 4417703,1,"Measured discharge 2.2 gpm. Dec.10","1965. Specific conductance, field " 4417703,2,"test, 1100. Temp. 67 degrees F ", 4417704,1,"Reported yield 175 gpm ", 4417706,1,"Perforated casing from 128 to 168 ","ft. " 4417708,1,"Well 275. ", 4417805,1,"Reported yield, 250 gpm. ", 4417806,1,"Reported yield, 200 gpm. ", 4418102,1,"Well 271. ", 4418107,1,"Preston Supply unit, water supply ","well 14. Slotted casing from 100 " 4418107,2,"to 190 ft and 225 to 268 ft. ","Reported yield 60 gpm. " 4418108,1,"Preston Supply Unit, water supply ","well 9. " 4418110,1,"Preston Supply Unit, water supply ","well 15. Slotted casing from " 4418110,2,"115 to 256 ft. Reported yield ","88 gpm. " 4418111,1,"Preston Supply Unit, water supply ","well 19. Slotted casing from 130 " 4418111,2,"to 254 ft. Reported yield 60 gpm. ", 4418112,1,"Shackelford Supply Unit, water ","supply well 1. Slotted casing " 4418112,2,"from 90 to 180 ft and 223 to 263 ","ft. " 4418113,1,"Shackelford Supply Unit, water ","supply well 2. Slotted casing from" 4418113,2,"92 to 193 ft and 218 to 261 ft. ","Reported yield 22 gpm. " 4418114,1,"Shackelford Supply Unit, water ","supply well 3. Slotted casing from" 4418114,2,"118 to 138 ft and 220 to 245 ft. ", 4418115,1,"Shackelfor Supply Unit, water ","supply well 4. Slotted casing " 4418115,2,"from 120 tp 125 ft; 140 to 155 ft; ","184 to 204 ft; and 215 to 231 ft. " 4418116,1,"Shackelfor Supply Unit, water ","supply well 5. Slotted casing " 4418116,2,"from 125 to 155 ft; 170 to 180 ft; ","and 215 to 230 ft. " 4418117,1,"Shackelford Supply Unit, water ","supply well 6. Slotted casing " 4418117,2,"fro 125 to 165 ft; 170 to 199 ft; ","and 210 to 248 ft. " 4418118,1,"Shackelford Supply Unit, water ","supply well 8. Slotted casing from" 4418118,2,"130 to 264 ft. Reported yield 60 ","gpm. " 4418119,1,"Shackelford Supply Unit, water ","supply well 9. Slotted casing " 4418119,2,"from 130 to 165 ft. Reported yield","80 gpm. " 4418120,1,"Shackelford Supply Unit, water ","supply well 11. Slotted casing " 4418120,2,"from 130 to 263 ft. Reported ","yield 95 gpm. " 4418121,1,"Shackelford Supply Unit, water ","supply well 14. Slotted casing " 4418121,2,"from 190 to 246 ft. ", 4418122,1,"Shackelfor Supply Unit, water ","supply well 15. " 4418123,1,"Shackelford Supply unit, water ","supply well 16. Slotted casing " 4418123,2,"from 198 to 253 ft. Reported yield","40 gpm. " 4418124,1,"Schakelford Supply Unit, water ","supply well 17. Slotted casing " 4418124,2,"from 165 to 250 ft. Reported ","yield 30 gpm. " 4418125,1,"Shackelford Supply Unit, water ","supply well 19. Slotted casing " 4418125,2,"fro 200 to 255 ft. Reported yield ","45 gpm. " 4418126,1,"Shackelford Supply Unit, water ","supply well 20. Slotted casing " 4418126,2,"from 200 to 255 ft. Reported yield","45 gpm. " 4418127,1,"Shackelford Supply Unit, water ","supply well 21. Slotted casing " 4418127,2,"from 200 to 257 ft. Reported yield","65 gpm. " 4418128,1,"Shackelford Supply Unit, water ","supply well 23. Slotted casing " 4418128,2,"from 200 to 257 ft. ", 4418129,1,"Shackelford Supply Unit, water ","supply well 24. Slotted casing " 4418129,2,"from 135 to 250 ft. Reported yield","80 gpm. " 4418130,1,"Shackelford Supply Unit, water ","supply well 25. Slotted casing " 4418130,2,"from 180 to 250 ft. Reported yield","70 gpm. " 4418131,1,"Shackelford Supply Unit, water ","supply well 28. " 4418132,1,"Shackelford Supply Unit, water ","supply well 29. Slotted casing " 4418132,2,"from 112 to 245 ft. Reported yield","75 gpm. " 4418133,1,"Shackelford Supply Unit, water ","supply well 30. Slotted casing " 4418133,2,"from 158 to 245 ft. Reported ","yield 100 gpm. " 4418134,1,"Shackelford Supply Unit, water ","supply well 31. Slotted casing " 4418134,2,"from 185 to 249 ft. Reported yield","70 gpm. " 4418135,1,"Shackelford Supply Unit, water ","supply well 32. Slotted casing " 4418135,2,"from 112 to 245 ft. Reported yield","80 gpm. " 4418136,1,"Shackelford Supply Unit, water ","supply well 33. Slotted casing " 4418136,2,"from 112 to 240 ft. Reported ","yield 100 gpm. " 4418137,1,"Shackelford Supply Unit, water ","supply well 18. Slotted casing " 4418137,2,"from 120 to 253 ft. Reported yield","50 gpm. " 4418201,1,"Perforated casing. Reported yield ","43 gpm. " 4418205,1,"Preston Supply Unit, water supply ","well 10. " 4418206,1,"Preston Supply Unit, water supply ","well 11. " 4418207,1,"Preston Supply Unit, water supply ","well 16. Slotted casing from 190 " 4418207,2,"to 260 ft. Reported yield 40 gpm. ", 4418208,1,"Preston Supply Unit water supply ","well 17. Reported yield 84 gpm. " 4418209,1,"Preston Supply Unit, water supply ","well 18. Slotted casing from 118 " 4418209,2,"to 249 ft. Reported yield 80 gpm. ", 4418210,1,"Preston Supply unit, water supply ","well 20. Slotted casing from 110 " 4418210,2,"to 255 ft. Reported yield 50 gpm. ", 4418211,1,"Preston Supply Unit, water supply ","well 27. Slotted casing from 195 " 4418211,2,"to 241 ft. Reported yield 60 gpm. ", 4418213,1,"Reported yield 36 gpm. Perforated ","casing from 103 to 142 ft. " 4418214,1,"Observation well. Reported yield ","41 GPM. Measured yield 31.4 GPM " 4418214,2,"with 19.6 feet drawdown after ","pumping 4 hours in 2001. " 4418214,3,"Specific capacity 1.60 GPM/ft. ","Aquifer test analysis in TWDB file." 4418302,1,"Very rusty discharge pipe. ", 4418403,1,"Reported yield 60 gpm. ", 4418404,1,"Reported yield, 125 gpm. ", 4418405,1,"Unused irrigation well. Pumping ","water level 176 ft. Reported yield" 4418405,2,"100 gpm. ", 4418407,1,"Well drilled deeper in 1966. ","Perforated plastic casing from 125 " 4418407,2,"to 220 ft. Well 265 ", 4418411,1,"Reported yield 200 gpm. ", 4418412,1,"Reported yield 200 gpm. ", 4418421,1,"Preston Supply Unit, water supply ","well 2. " 4418422,1,"Preston Supply Unit, water supply ","well 3. " 4418423,1,"Preston Supply Unit, water supply ","well 6. " 4418424,1,"Preston Supply Unit, water supply ","well 7. " 4418501,1,"Preston Supply Unit, water supply ","well 10. Reported yield 40 gpm. " 4418502,1,"Perforated casing from 130 to 230 ","ft. Reported yield 90 gpm. " 4418503,1,"Reported yield, 150 gpm. ", 4418505,1,"Slotted casing from 120 to 143 ft ","and 170 to 190 ft. Reported yield," 4418505,2,"170 gpm. ", 4418506,1,"Well plugged. Reported yield 50 ","gpm. " 4418507,1,"Well plugged. Reported yield, 50 ","gpm. " 4418508,1,"Well capped. ", 4418509,1,"Slotted casing from 138 to 150 ft ","and 162 to 190 ft. " 4418510,1,"Slotted casing from 114 to 124 ft; ","129 to 146 ft; 151 to 197 ft; and " 4418510,2,"202 to 210 ft. Reported yield 150 ","gpm. " 4418511,1,"Unused industrial well. ", 4418512,1,"Slotted casing from 125 to 135 ft ","and 140 to 170 ft. Reported yield " 4418512,2,"60 gpm. ", 4418514,1,"Unused industrial well. Reported ","yield, 200 gpm. " 4418518,1,"Well 261. ", 4418519,1,"Preston Supply Unit, water supply ","well 1. " 4418520,1,"Preston Supply Unit, water supply ","well 4. " 4418521,1,"Preston Supply Unit, water supply ","well 5. " 4418522,1,"Preston Supply Unit, water supply ","well 12. " 4418523,1,"Preston Supply Unit, water supply ","well 13. " 4418601,1,"Reported yield 115 gpm. ", 4418602,1,"Reported yield, 160 gpm. ", 4418603,1,"Reported yield 150 gpm ", 4418702,1,"Temp 68 degrees F. ", 4418703,1,"Reported yield, 25 gpm. Well 263.","Original depth 127 ft; deepened to " 4418703,2,"260 ft in 1964. Pump set at 125 ft","Temp. 71 degrees F. " 4418801,1,"Converted oil test. Reported yield","113 GPM in 1961. " 4418802,1,"Reported yield 200 gpm. ", 4418803,1,"Unused irrigation well. Reported ","yield 40 gpm. " 4418804,1,"Unused irrigation well. Reported ","yield 80 gpm. Perforated casing " 4418804,2,"from 140 to 240 ft. ", 4418811,1,"Perforated casing from 100 to 260 ","ft. Reported yield 200 gpm. " 4418826,1,"Reported yield 200 gpm. ","Historical observation well. " 4418828,1,"Perforated casing from 100 to 280 ","ft. Reported yield, 180 gpm. " 4418829,1,"Formerly supplied water for ","drilling oil test. Irrigates 45 " 4418829,2,"acres of cotton. Reported yield ","300 gpm. " 4418904,1,"Perforated casing from 120 to 305 ","ft. Reported yield 200 gpm. " 4418905,1,"Unused irrigation well. Perforated","casing from 120 t 285 ft. " 4418905,2,"Reported yield 75 gpm. ", 4506301,1,"Well 7. ", 4506301,2,"Well depth was entered as 75 feet ","with no source of depth. No " 4506301,3,"documentation for where depth came ","from. Deleted well depth from " 4506301,4,"database. HR 10/25/10 ", 4506304,1,"Gravel packed from 64 to 150 ft. ","Cemented from 0 to 64 feet. " 4506305,1,"Gravel packed from 72 to 152 ft. ","Cemented from 0 to 72 feet. " 4506306,1,"Gravel packed from 73 to 152 ft. ","Cemented from 0 to 73 feet. " 4506307,1,"Gravel packed from 69 to 142 ft. ","Cemented from 0 to 69 feet. " 4506308,1,"Gravel packed from 73 to 152 ft. ","Cemented from 0 to 73 feet. " 4506309,1,"Gravel packed from 64 to 142 ft. ","Cemented from 0 to 64 feet. " 4506601,1,"Well 9. ", 4506606,1,"Oil test. ", 4506902,1,"Well 221. ", 4507102,1,"Well 10. ", 4507202,1,"Historical observation well. ", 4507415,1,"MP= +2.50 feet ", 4507502,1,"Historical observation well. ", 4507504,1,"Formerly well 45-07-417. Aquifer ","test results unnumbered in TWDB " 4507504,2,"R-98. Test results in TDWR R-235. ","No test data in TWDB files. " 4507504,3,"Page 379 in R-98. ", 4507602,1,"Historical observation well. ", 4507606,1,"Cemented from 0 to 10 feet. Gravel ","packed from 40 to 80 feet. " 4507704,1,"Well 219. ", 4507705,1,"Oil test. ", 4507707,1,"Historical observation well. ", 4508204,1,"Historical observation well. ", 4508311,1,"Test hole. ", 4508509,1,"Cemented from 0 to 54 feet. Gravel ","packed from 58 to 80 feet. " 4508701,1,"Well deepened in 1959. ", 4508801,1,"Historical observation well. ", 4515105,1,"Abandoned industrial well. ", 4515303,1,"Well 202. ", 4515701,1,"Cities Service Plant, water well ","1. " 4515702,1,"Historical observation well. ", 4515704,1,"Cities Service Plant, water well 2.","Slotted casing from 125 to 180 ft. " 4515705,1,"Cities SErvice Plant water well 3. ","Slotted casing from 125 to 185 ft. " 4515706,1,"Cities Service Plant water well 4. ","Slotted casing from 125 to 185 ft. " 4522302,1,"Called the Frijol wm on topo map. ", 4522901,1,"Abandoned irrigation well. ", 4522902,1,"Abandoned irrigation well. ", 4522903,1,"Abandoned irrigation well. ","Historical observation well. " 4523402,1,"Well depth entered as 156 with no ","source of depth. Water level from " 4523402,2,"1937 is considerably deeper than ","depth. No documentation for where " 4523402,3,"depth value came from. Deleted well","depth from database. HR 10/26/10 " 4523404,1,"Well destroyed. 8/16/07 ", 4523603,1,"Well 291. ", 4523704,1,"Oil test. ", 4523706,1,"Perforated casing. ", 4523706,2,"Well may be dry. Pumping but no ","water discharging. 8/16/07 " 4523904,1,"Converted oil test. Reported yield ","98 GPM with 383 feet drawdown after" 4523904,2,"pumping 2 months in 1958. Original ","depth 5569 feet. " 4523905,1,"Pegasus Plant #9. Reported yield 35","gpm with 38.9 ft drawdown in 1959. " 4523907,1,"Converted oil test. Reported yield ","148 GPM with 844 feet drawdown " 4523907,2,"after pumping 8 hours in 1955: and ","73 GPM with 783 feet drawdown after" 4523907,3,"pumping 5 days in 1956. Plugged ","back to 1300 feet in 1958. Reported" 4523907,4,"yield 35 GPM with 340 feet drawdown","after pumping 35 days in 1958. Well" 4523907,5,"deepened to 5525 feet in 1961. ","Stand by well in 1965. " 4523908,1,"Pegasus Plant Camp, water well 3. ","Reported yield 28 gpm in July,1953." 4523908,2,"Specific conductance, field test, ","890. Formerly supplied oil field " 4523908,3,"camp; now supplies Pegasus Plant. ", 4523909,1,"Pegasus Plant, water well 1. ","Reported yield, 20 gpm. " 4523909,2,"Reported drawdown: 22.5, 27.5, and ","42.5 ft discharging 23, 21.4, 19.5 " 4523909,3,"gpm in 1953, 1958, and Apr. 1965 ","respectively " 4523910,1,"Pegasus Plant, water well 3. ","Reported yield, 35 gpm. " 4523910,2,"Specific conductance, field test, ","890. Reported discharge 35 gpm, " 4523910,3,"Dec. 1951. Pump set at 225 ft. ","Temp. 67 degrees F. " 4523911,1,"Pegasus Plant, water well 4. ","Reported drawdowns: 19 and 4.9 ft " 4523911,2,"discharging 32.5 and 8.3 gpm in ","1955 and Apr. 1965, respectively. " 4523912,1,"Pegasus Plant, water well 5. ","Reported drawdowns: 15.8 and 29.3 " 4523912,2,"ft discharging 7.1 and 8 gpm in ","1956 and 1959 respectively. " 4523913,1,"Pegasus Plant, water well 6. ","Reported yield 22 gpm. " 4523913,2,"Reported drawdowns: 22 ft discharg-","ing 21.9 gpm for 24 hours in Apr. " 4523913,3,"1965. Pump set at 231 ft. ", 4523914,1,"Pegasus Plant, water well 7. ","Reported drawdown: 49 ft discharg- " 4523914,2,"ing 28.5 gpm in 1958. Pump set at ","240 ft. " 4523919,1,"Historical observation well. ","Casing collapsed at 165' in 2005. " 4524101,1,"Well depth was reported at 100' in ","1967, may have caved in to this " 4524101,2,"depth. Original well depth was ","reported as 129' in report M187. " 4524302,1,"Well 281. ", 4524305,1,"Well 279. ", 4524401,1,"Reported yield 62 GPM. ", 4524501,1,"Well 290. ", 4524502,1,"Old oil test converted to water ","well. Well 289. " 4524801,1,"Measured discharge 2.6 gpm, Dec.4, ","1965. Specific conductance, field " 4524801,2,"test, 925. Temp. 67 degrees F. ", 4524802,1,"Measured discharge 2.4 gpm, Dec.4, ","1965. Specific conductance, field " 4524802,2,"test, 775. 2 1/2in. column pipe. ",