"state_well_number","group_number","remarks_1","remarks_2" 3819701,1,"Oil test. ", 3825501,1,"Oil test. ", 3825601,1,"Oil test. ", 3825701,1,"Abandoned. ", 3825702,1,"Open ended below 400 ft. Water is ","dark and has slight hydrogen " 3825702,2,"sulfide odor. ", 3825707,1,"Owners Keechi well. Reported yield ","150 gpm with 230 feet drawdown " 3825707,2,"after pumping 24 hours in 1984. ","Specific capacity 0.65 gpm/ft. " 3825707,3,"TCEQ ID #G1450015C. ", 3825801,1,"Oil test. ", 3825802,1,"Oil test. ", 3825803,1,"Oil test. ", 3825901,1,"Oil test. ", 3825902,1,"Oil test. ", 3825903,1,"Oil test. ", 3826101,1,"Abandoned. Drilled in early ","1930's. Owner now uses city water." 3826102,1,"Reported yield 151 GPM in 1959. ","Aquifer test results in TWB R-98. " 3826102,2,"Test data in TWDB files. ", 3826109,1,"Reported yield 200 gpm with 128 ","feet drawdown after pumping 4 hours" 3826109,2,"in 1979. Specific capacity 1.56 ","gpm/ft. " 3826109,3,"Pump pulled in 2011 and new well ","will be drilled near this one. " 3826109,4,"Camera survey done in 2011 and ","found hole in casing at 112 ft. " 3826201,1,"Owner's well no.1. Perforated from","220 to 420 ft. Yield reported at " 3826201,2,"900 gpm. 1. 3. ", 3826202,1,"Owner's well no.2. Perforated from","250 to 450 ft. Yield reported at " 3826202,2,"350 gpm. 1. 3. ", 3826401,1,"Owners well #4. Measured yield 175 ","GPM with 100 feet drawdown after " 3826401,2,"pumping 24 hours in 1993. Specific ","capacity 1.75 GPM/ft. Pumping level" 3826401,3,"195 feet. Cemented from 0 to 740 ","feet. Underreamed and gravel " 3826401,4,"packed. ", 3826501,1,"Oil test. ", 3826502,1,"Oil test. ", 3826503,1,"Oil test. ", 3826701,1,"Perforated 325-400 ft. Estimated ","flowing 115 gpm. Casing dropped " 3826701,2,"1.5 ft. September 1, 1958, and ","well stopped flowing through pipe. " 3826701,3,"Water is coming up the outside of ","the casing. " 3826702,1,"Oil test. ", 3826703,1,"Oil test. ", 3826704,1,"Oil test. ", 3826705,1,"Oil test. ", 3826801,1,"Oil test. ", 3826802,1,"Oil test. ", 3826803,1,"Oil test. ", 3826901,1,"Oil test. ", 3826902,1,"Oil test. ", 3826903,1,"Oil test. ", 3826904,1,"Measured yield 43 GPM in 1969. ","Cemented. Pump set at 105 feet. " 3827403,1,"Oil test. ", 3833201,1,"Oil test. ", 3833202,1,"Oil test. ", 3833301,1,"Casing to 270 ft. Strong flow ","through rusted-out pipe. At one " 3833301,2,"time was used for canning factory. ", 3833302,1,"Cased to 400 ft. Open ended and ","gravel packed to TD. Slight " 3833302,2,"leakage around packer while ","measuring. Flows. " 3833303,1,"Flows. ", 3833304,1,"Perforated 140-180 ft. Reported ","60 ft. of 5 in. surface pipe. " 3833304,2,"flows. ", 3833305,1,"Oil test. ", 3833306,1,"Oil test. ", 3833401,1,"Oil test. ", 3833402,1,"Oil test. ", 3833403,1,"Owner's #1 well. Originally drilled","to 891 feet. Measured yield 189 GPM" 3833403,2,"with 65 feet drawdown after pumping","24 hours in 1980. Underreamed and " 3833403,3,"gravel packed from 443 to 617 feet.","Cemented from 0 to 517 feet. Pump " 3833403,4,"set at 231 feet. Specific capacity ","2.91 GPM/ft. PWS ID #1450015A. " 3833501,1,"Perforated 371-411 ft. Temporary ","well to supply oil rig. " 3833502,1,"Oil test. ", 3833503,1,"Oil test. ", 3833504,1,"4. 5. ", 3833505,1,"Owner's #2 well. Originally drilled","to 600 feet. Measured yield 212 GPM" 3833505,2,"with 85 feet drawdown after pumping","24 hours in 1984. Underreamed and " 3833505,3,"gravel packed from 400 to 552 feet.","Cemeted from 0 to 463 feet. Pump " 3833505,4,"set at 253 feet. Specific capacity ","2.49 GPM/ft. PWS ID #1450015B. " 3833701,1,"Oil test. ", 3833702,1,"Oil test. ", 3833801,1,"Screened from 580 to 620 ft. 1. ", 3833803,1,"Screen 590-614 ft. Pump set at 80 ","ft. " 3833804,1,"Oil test. ", 3834101,1,"Abandoned. Open ended below 150 ","ft. Seismograph shot hole which " 3834101,2,"owner cased. It flowed until the ","summer of 1956. " 3834102,1,"Some leakage from holes in the pipe","while measuring. Flows " 3834104,1,"Flows. ", 3834105,1,"Flows. ", 3834106,1,"Oil test. ", 3834107,1,"Oil test. ", 3834108,1,"Oil test. ", 3834109,1,"Oil test. ", 3834110,1,"Oil test. ", 3834111,1,"Oil test. ", 3834201,1,"Oil test. ", 3834301,1,"Abandoned industrial well. ","Formerly used as an oil rig supply " 3834301,2,"well. 1. ", 3834302,1,"Oil test. ", 3834303,1,"Oil test. ", 3834304,1,"Oil test. ", 3834305,1,"Oil test. ", 3834306,1,"Oil test. ", 3834401,1,"1. 3. ", 3835401,1,"1. 4. ", 3835701,1,"Oil test. ", 3841101,1,"Oil test. ", 3841201,1,"Oil test. ", 3841202,1,"Oil test. ", 3841204,1,"Oil test. ", 3841501,1,"Oil test. ", 3841502,1,"Oil test. ", 3841601,1,"Oil test. ", 3841701,1,"Reported yield 67 GPM with 33 feet ","drawdown in 1959. Aquifer test res-" 3841701,2,"ults in TWDB R-98. Test data in ","TWDB files. Historical observation " 3841701,3,"well. ", 3841702,1,"Screen 299-346 ft. Pump set at 130","ft. " 3841703,1,"Oil test. ", 3841705,1,"Screened from 480 to 630 ft. Open ","hole from 630 to 1197 ft. Yield " 3841705,2,"measured at 550 gpm with a drawdown","of 100 ft on a 36 hour test on " 3841705,3,"Aug. 14,1970. Specific capacity of","5.5 gpm/ft. Electric log Q-253 in " 3841705,4,"the files of the Texas Water Comm- ","ission. 2. 5. " 3841706,1,"Owner's #4 well. Measured yield 300","GPM with 95 feet drawdown after " 3841706,2,"pumping 36 hours in 1986. Under- ","reamed and gravel packed from 932 " 3841706,3,"to 1022 feet. Cemented from 0 to ","932 feet. Pump set at 357 feet. " 3841707,1,"Owner's #5 well. Underreamed and ","gravel packed. Cemented from 0 to " 3841707,2,"1190 feet. This is city's primary ","well. " 3841708,1,"Owners System #1 well #5. PWS ID ","#1450027C. Reported yield 200 GPM. " 3841708,2,"Pump set at 400 feet. Cemented from","0 to 1100 feet. Gravel packed from " 3841708,3,"995 to 1184 feet. Drillers report ","tracking #133144. " 3841901,1,"Owner's #1 well. Geophysical log. ","Originally drilled to 1160 feet. " 3841901,2,"Maeasured yield 179 GPM with 32 ","feet drawdown after pumping 36 " 3841901,3,"hours in 1989. Gravel packed and ","underreamed from 714 to 805 feet. " 3841901,4,"Cemented from 0 to 714 feet. ", 3841902,1,"Owners System #1 well #6. PWS ID ","#1450027B. Reported yield 200 GPM. " 3841902,2,"Pump set at 315 feet. Cemented from","0 to 699 feet. Gravel packed from " 3841902,3,"632 to 801 feet. Drillers report ","tracking #133125. " 3842101,1,"Oil test. ", 3842102,1,"Oil test. ", 3842301,1,"Has high iron content. ", 3842303,1,"Oil test. ", 3842501,1,"Oil test. ", 3842701,1,"Screen 576-600 ft. Pump set at 160","ft. " 3842702,1,"Screen 598-618 ft. Pump set at 210","ft. Historical observation well. " 3842702,2,"Plugged domestic well in 1997. ", 3842703,1,"Screen 576-600 ft. Pump set at 150","ft. Reported sand 134-177 ft. " 3842703,2,"contained iron water. Sand 220-260","ft. Sand 278-312 ft. contained " 3842703,3,"iron water, water level 92 ft. ", 3842704,1,"Oil test. ", 3843101,1,"Originally drilled to 1152 feet as ","an oil test. Plugged back to 676 " 3843101,2,"feet and completed as water well. ","Reported yield 850 GPM in 1959. " 3843101,3,"Electric log Q-16 in the files of ","the Texas Water Commission. " 3843101,4,"Aquifer test results in TWDB R-98. ","Test data in TWDB files. " 3843102,1,"Screen 600-681 ft. Supplies ","several houses. " 3843103,1,"Screen 259-289 ft. Water contains ","some iron which is filtered with " 3843103,2,"zeolite. Pump set at 139 ft. ", 3843105,1,"Temporary well to supply oil rig. ", 3843106,1,"Oil test. ", 3843107,1,"Oil test. ", 3843108,1,"Oil test. ", 3843201,1,"1. 3. ", 3843202,1,"Owner's well no.3. Slotted from ","536 to 596 ft. 1. " 3843401,1,"Oil test. ", 3843402,1,"Oil test. ", 3843501,1,"Perforated 288-328 ft. Well ","drilled to supply oil rig. Oil rig" 3843501,2,"reported hitting strong stream of ","water between 600 and 700 ft. " 3843501,3,"Flows. ", 3849202,1,"Oil test. ", 3849301,1,"Oil test. ", 3849302,1,"Oil test. ", 3849501,1,"Abandoned. ", 3849502,1,"Owner's #2 well. Geophysical log. ","Measured yield 201 GPM with 23 feet" 3849502,2,"down after pumping 36 hours in ","1989. Specific capacity 8.7 GPM/ft." 3849502,3,"Aquifer test data in TWDB files. ", 3849601,1,"Screen 397-412 ft. Pump set at ","63 ft. " 3849602,1,"Oil test. ", 3849701,1,"Oil test. ", 3849703,1,"Oil test. ", 3849801,1,"Oil test. ", 3849802,1,"Screened from 1019 to 1049, and ","1059 to 1079 ft. Gamma Ray log in " 3849802,2,"the files of the Texas Water Devel.","Board. 4. 5. " 3850101,1,"Well abdn. and plugged. ", 3850102,1,"Well replaces 38-50-101. ", 3850201,1,"Open hole from 496 to 1020 ft. ", 3850401,1,"Has iron. ", 3850402,1,"Has some iron. ", 3850601,1,"Oil test. ", 3850701,1,"Oil test. ", 3850801,1,"Oil test. ", 3857101,1,"Oil test. ", 3857201,1,"Oil test. ", 3858301,1,"Oil test. ", 3939405,1,"Slotted 540 to 650 ft. Yield ","reported at 75 gpm. 5. " 3939701,1,"Reports trouble with well sanding ","up. " 3939703,1,"Unused domestic or livestock well. ", 3939704,1,"Oil test. ", 3939705,1,"Owners well #2. PWS ID #1450024B. ","Reported yield 310 GPM with 161.6 " 3939705,2,"feet drawdown after pumping 36 ","hours in 2002. Specific capacity " 3939705,3,"1.92 GPM/ft. Pumping level 327 ","feet. Pump set at 425 feet. Cement-" 3939705,4,"ed from 0 to 595 feet. Gravel pack-","ed from 595 to 780 feet. " 3939801,1,"Screen 307-328 ft. ", 3939901,1,"1. 3. ", 3939902,1,"Screen 461-481 ft. Water contains ","some iron. " 3939903,1,"Destroyed public supply well. ","Originally drilled to 1112 feet. " 3939903,2,"Cement plug set at 940 feet. ","Reported yield 70 GPM in 1984. " 3940201,1,"Screened from 642 to 682 ft. ","Yield reported at 120 gpm. 1. " 3940202,1,"Screened from 619 to 681 ft, Yield","reported at 120 gpm. 1.5. " 3940203,1,"Screened from 690 to 710 ft. Yield","reported at 33 gpm with a drawdown " 3940203,2,"of 100 ft on a 12 hour test. ","Specific capacity of 0.3 gpm/ft. " 3940203,3,"3. ", 3940204,1,"Oil test. ", 3940205,1,"Owner's 164 well. Originally drill-","ed to 951 feet. Measured yield 153 " 3940205,2,"GPM with 265 feet drawdown after ","pumping 24 hours in 1980. Under- " 3940205,3,"reamed and gravel packed from 795 ","to 871 feet. Cemented from 0 to 795" 3940205,4,"and 871 to 951 feet. ", 3940301,1,"Screen 650-690 ft. Furnishes water","for seven families and a swimming " 3940301,2,"pool. Water in sand at 400 ft. ","reported high in iron. " 3940302,1,"Screen 650-690 ft. Abandoned oil ","test plugged at 690 ft. Reported " 3940302,2,"by owner to flow 7 gpm when pump is","shut off. " 3940303,1,"Perforated 65-92 ft. Open ended ","and gravel packed from 92 ft. TD. " 3940303,2,"Water has some iron. ", 3940304,1,"Screened from 556 to 576 ft. ","1. 4. " 3940305,1,"Screen 708-740 ft. Supplies two ","houses. Pump set at 120 ft. " 3940306,1,"Oil test. ", 3940401,1,"Screened from 685 to 720 ft. 5. ", 3940501,1,"1. ", 3940502,1,"Screen 618-638 ft. Reported ","measurement taken immediately after" 3940502,2,"jetting the well. Pump set at 125 ","ft. " 3940503,1,"Screen 615-635 ft. Reported 10 ft.","drawdown after 24 hours of jetting " 3940503,2,"a 4 in. screen. ", 3940504,1,"Oil test. ", 3940601,1,"Perforated from 371 to 391 ft. ","1. 4. " 3940602,1,"Oil test. ", 3940603,1,"Oil test. ", 3940604,1,"Unused public supply well. Measured","yield 210 GPM with 176 feet draw- " 3940604,2,"down after pumping 36 hours in ","1992. Gravel packed and underreamed" 3940604,3,"from 612 to 710 feet. Cemented from","0 to 610 feet. " 3940605,1,"Measured yield 250 GPM with 221 ","feet drawdown after pumping 24 " 3940605,2,"hours in 1995. Underreamed and ","gravel packed from 650 to 700 feet." 3940605,3,"Cemented from 0 to 650 feet. ","Specific capacity 1.13 GPM/ft. " 3940605,4,"Owners well #4. PWS ID #1450015D. ", 3940701,1,"Screen 400-450 ft. Water in sand ","at 250 ft. reported high iron " 3940701,2,"content, cased off. Well has water","with high iron content and alum " 3940701,3,"taste. Used for all household use ","except drinking. Possible leakage." 3940701,4,"Water quality report from 1958 list","pH value of 3.3. This seems low but" 3940701,5,"is also consistent with comments ","regarding Fe above. Not enough " 3940701,6,"documentation to support changing ","value in db. HR 10/9/08. " 3940702,1,"Owner's Weeden Test hole site. ","Plugged. Measured yield 30 GPM with" 3940702,2,"70 feet drawdown after pumping 4 ","hours in 1984. " 3940901,1,"Perforated 160-180 ft. Drilled to ","310 ft. plugged back to 180 ft. " 3940901,2,"because of oil and gas. Water was ","good when first completed, now has " 3940901,3,"too much iron and oil to drink. ", 3940902,1,"Abandoned. Temporary well to ","supply oil rig. Reported not to " 3940902,2,"have iron strain. ", 3940903,1,"Oil test. ", 3940906,1,"Completed from 790 to 820 ft. ","4. " 3946301,1,"1. ", 3946601,1,"1. ", 3946801,1,"Oil test. ", 3946901,1,"Unused domestic and stock well. ","Perforated from 603 to 666 ft. " 3946901,2,"Historical observation well. ", 3946902,1,"Completed from 540 to 570 ft. ","Historical observation well. " 3947101,1,"Screen 317-337 ft. Pump set at 153","ft. " 3947102,1,"Slotted from 615 to 625 ft. ","5. " 3947301,1,"Unused public supply well. Screen-","ed from 309 to 331, 348 to 370, and" 3947301,2,"380 to 394 ft. Yield reported at ","180 gpm. 1. 5. " 3947302,1,"Screened from 620 to 640 ft. Yield","reported at 150 gpm. 1. " 3947303,1,"Owner's well no.2. Screened from ","545 to 565, 575 to 595, 625 to 635," 3947303,2,"and 640 to 660 ft. Yield reported ","at 178 gpm with a drawdown of 110 " 3947303,3,"ft on an 8 hour test on Sept.28, ","1970. Specific capacity of 1.6 gpm" 3947303,4,"/ft. Electric log Q-525 in the ","files at the Texas Water " 3947303,5,"Commission. 5. ", 3947304,1,"Owner's well no.3. Screened from ","856 to 908 and 969 to 1033 ft. " 3947304,2,"Yield reported at 250 gpm with a ","drawdown of 85 ft on a 24 hour test" 3947304,3,"on Sept. 28, 1983. Specific ","capacity of 2.9 gpm/ft. Electric " 3947304,4,"log in the files of the Texas Water","Development Board. 5. " 3947401,1,"Screen 463-475 ft. Pump set at 132","ft. " 3947402,1,"Dug. Concrete casing with 2 ft. of ","gravel on the bottom. Supply " 3947402,2,"small, but adequate for owner's ","use. " 3947403,1,"Formerly used as public supply for ","school. " 3947501,1,"Screen 572-597 ft. Pump set at 192","ft. " 3947502,1,"Screen 527-537 ft. ", 3947503,1,"Well #7. Reported yield 305 GPM ","with 124 feet drawdown after pump- " 3947503,2,"ing 36 hours in 2004. Specific cap-","acity 2.4 GPM/ft. " 3947503,3,"TCEQ # 1450018. ", 3947503,4,"TR# 80984. ", 3947602,1,"Abandoned industrial well. ","Originally drilled to supply an oil" 3947602,2,"rig. 1. 4. ", 3947603,1,"Abandoned. Well drilled to supply ","oil rig. " 3947604,1,"Oil test. ", 3947701,1,"Casing to 400 ft., open ended to ","bottom. " 3947702,1,"Perforated at several levels below ","260 ft. Pump set at 147 ft. " 3947703,1,"Screen 534-564 ft. Drilled to 500 ","ft. in December 1955, then deepened" 3947703,2,"in March 1956. Pump set at 140 ft.", 3947904,1,"Screened from 560 to 595 ft. 3. ", 3947905,1,"Owner's #1 well. Measured yield 104","GPM with 78 feet drawdown after " 3947905,2,"pumping 24 hours in 1982. Specific ","capacity 1.3 GPM/ft. Aquifer test " 3947905,3,"data in TWDB files. ", 3947906,1,"Owners well Remote-5. Cemented from","0 to 355 feet. " 3947907,1,"Owners well Remote-8. Cemented from","0 to 339 feet. " 3948101,1,"Screened from 360 to 380 ft. ","Destroyed. " 3948102,1,"Oil test. ", 3948301,1,"Abandoned. ", 3948401,1,"Slotted from 280 to 440 ft. ", 3948701,1,"Owners well Hitt-8. Cemented from 0","to 470 feet. " 3948702,1,"Owners well Hitt-5. Cemented from 0","to 420 feet. " 3948801,1,"Oil test. ", 3948901,1,"Oil Test. ", 3954301,1,"Screen 181-201 ft. ", 3954302,1,"Cased to 350 ft. Perforated 339- ","350 ft. Having trouble with the " 3954302,2,"well sanding up. ", 3954303,1,"Destroyed public supply well. ","Screened from 350 to 371 and 601 " 3954303,2,"to 678 ft. 1. ", 3954304,1,"Unused public supply well. ", 3954306,1,"Owner's well #3. Reported yield 160","GPM with 80 feet drawdown after " 3954306,2,"pumping 36 hours in 1991. Specific ","capacity 2.0 GPM/ft. Aquifer test " 3954306,3,"data in TWDB files. ", 3954603,1,"Destroyed test hole. Geophysical ","logs in the files of the Texas " 3954603,2,"Water Development Board. ","5. " 3954604,1,"Test hole. Slotted from 116 to ","200 ft. Geophysical logs in the " 3954604,2,"files of the Texas Water Dev. Board",". 5. " 3954901,1,"Perforated 207-227 ft. Water ","contains iron; probably it is from " 3954901,2,"upper sands. ", 3954902,1,"Perforated 188-230 ft. Pump set at","80 ft. " 3954903,1,"Perforated 270-310 ft. ", 3954904,1,"Screen 204-224 ft. Supplies two ","families. Water has slight oil " 3954904,2,"taste from used oil wel1 casing. ", 3954905,1,"Perforated 340-380 ft. Pump set at","80 ft. Water Contains some iron. " 3954905,2,"Owner believes the iron is coming ","from an old pipe. " 3954906,1,"Perforated from 252 to 294 ft. ","1. 3. " 3955101,1,"Screen 497-532 ft. 4 in. casing ","cemented to 230 ft. " 3955202,1,"Screened from 488 to 500 ft. ","1. " 3955204,1,"Well #6. Reported yield 556 GPM ","with 55 feet drawdown after pumping" 3955204,2,"24 hours in 2004. Specific capacity","10.1 GPM/ft. " 3955204,3,"TCEQ# 1450018. ", 3955204,4,"TR# 80981. ", 3955301,1,"Has some iron. ", 3955702,1,"Screen 598-622 ft. Pump set at 180","ft. Well originally was 480 ft. " 3955702,2,"Deepened because of high iron ","content in the water. Supplies " 3955702,3,"three houses. ", 3955801,1,"Screen 633-657 ft. Pump set at 270","ft. " 3955802,1,"Screen 756-776 ft. Pump set at 250","ft. Well drilled to 420 ft. and " 3955802,2,"pipe set. Water contained iron. ","Drilled out screen and went to 776 " 3955802,3,"ft. Well has a little iron, ","probably coming through old screen " 3955802,4,"at 400-420 ft. ", 3955803,1,"Screen 750-770 ft. To be used ","later. " 3955804,1,"Screened from 770 to 800 ft. ", 3955901,1,"Oil test. ", 3956101,1,"Oil test. ", 3956102,1,"Second from 612 to 632 ft. 5. ", 3956402,1,"Oil test. ", 3956801,1,"Oil test. ", 3956802,1,"Owner's #3 well. Measured yield 140","GPM with 42 feet drawdown after " 3956802,2,"pumping 36 hours in 1989. Under- ","reamed and gravel packed from 920 " 3956802,3,"to 1026 feet. Cemented from 0 to ","922 feet. " 3956901,1,"Has too much iron for domestic use.", 3962301,1,"Perforated 315-357 ft. Pump set at","60 ft. " 3963101,1,"Perforated 273-336 ft. ", 3963102,1,"Perforated 273-315 ft. Well just ","completed; domestic and stock uses " 3963102,2,"planned. ", 3963301,1,"Screen 347-367 ft. Water has some ","iron, but did not have when first " 3963301,2,"drilled. ", 3963401,1,"Oil test. ", 3963402,1,"Owner's well #3 (Maintance Pumping ","Station). " 3963501,1,"Owners well #13. PWS ID #1450006U. ", 3963801,1,"Screened from 486 to 506 ft. ", 3963801,2,"Well at City Park. ", 3964101,1,"Oil test. ", 3964201,1,"Oil test. ", 3964202,1,"Oil test. ", 3964401,1,"Screen 308-320 ft. ", 3964402,1,"Screen 358-370 ft. ", 3964403,1,"Oil test. ", 3964404,1,"Oil test. ", 3964405,1,"Oil test. ", 3964501,1,"Oil test. ", 3964701,1,"Owner's #1 well. Plugged. Reported ","yield 140 GPM. " 3964705,1,"Owner's #1R well. Measured yield ","146 GPM with 18 feet drawdown after" 3964705,2,"pumping 24 hours in 1991. Gravel ","packed and underreamed from 1080 to" 3964705,3,"1202 feet. Cemented from 0 to 1080 ","feet. "