"state_well_number","group_number","remarks_1","remarks_2" 4045501,1,"Historical observation well. ", 4045701,1,"Owner's Winkler Park well. ","Formerly used as PS well. " 4045701,2,"Airline measurements taken between ","1993 & 2008 were found to be " 4045701,3,"incorrect and removed from database"," in 2011. " 4045701,4,"GCD well #N2-04-003G. ", 4045801,1,"Historical observation well. ", 4045802,1,"Historical observation well. ", 4045803,1,"Historical observation well. ", 4045804,1,"Historical observation well. ", 4045901,1,"Historical observation well. ", 4045902,1,"Historical observation well. ", 4045903,1,"Geophysical log Q-5. ", 4046901,1,"Pump set at 420 ft. ", 4051801,1,"Pumping level 384 ft at 26 gpm on ","Jan.9,1943. Originally drilled as " 4051801,2,"oil test. Abandoned and plugged. ", 4052201,1,"Historical observation well. ", 4052202,1,"Historical observation well. ", 4052302,1,"Owner's Owl Creek Park well. ","Measured yield 275 GPM with 58 feet" 4052302,2,"drawdown after pumping 24 hours in ","1960. Specific capacity 4.74 GPM/ft" 4052303,1,"Inactive PS well. TCEQ's ID#014163.", 4052601,1,"Historical observation well. ", 4052801,1,"Historical observation well. ", 4052802,1,"Historical observation well. ", 4052901,1,"Historical observation well. ", 4052902,1,"Historical observation well. ", 4052903,1,"Owner's West Cliff Park #2. ", 4053102,1,"Owner's Leona Park #1. Reported ","yield 10 GPM with 342 feet drawdown" 4053102,2,"after pumping 24 hours in 1962. ","Specific capacity 0.029 GPM/ft. " 4053102,3,"Cemented from 0 to 907 feet. Pump ","set at 362 feet. " 4053102,4,"Two aquifer tests in TWDB files. ","GCD well #N2-04-002G. " 4053103,1,"Owner's White Flint Park well. ", 4053201,1,"Owner's #3 well. Measured yield 30 ","GPM. " 4053301,1,"Owners well #1. Yield 16 gpm with a","drawdown of 20 feet after one hour." 4053301,2,"Specific capacity 0.8 GPM/ft. ","Cemented from 0 to 1015 feet. " 4053302,1,"Owners well #2. Yield 16 gpm with a","drawdown of 20 feet after one hour." 4053302,2,"Historical observation well. ","Cemented from 0 to 1015 feet. " 4053302,3,"Specific capacity 0.8 GPM/ft. ","Pump set at 609 feet. " 4053401,1,"Historical observation well. ", 4053402,1,"Historical observation well. ", 4053403,1,"Historical observation well. ", 4053404,1,"Unused public supply well. ", 4053405,1,"Measured yield 12 GPM with 30 feet ","drawdown after pumping 1 hour in " 4053405,2,"1974. Cemented from 0 to 1000 feet.", 4053406,1,"Owner's #1 well. Measured yield 120","GPM with 36.4 feet drawdown after " 4053406,2,"pumping 41 hours in 1967. ","Specific capacity 0.31 GPM/ft.\\ " 4053406,3,"Cemented from 0 to 1075 feet. ","Pump set at 506 feet. TWDB R-98. " 4053406,4,"Old well #AX37. ","Aquifer test results in TWDB R-195." 4053406,5,"Was formerly 40-53-505 until ","location was corrected in 2008. " 4053406,6,"GCD well #N-02-022G. ", 4053501,1,"Historical observation well. ", 4053504,1,"Owner's Cedar Ridge Park #1. ","Reported yield 10 GPM with 57 feet " 4053504,2,"drawdown after pumping 24 hours in ","1963. Specific capacity 0.17 " 4053504,3,"GPM/ft. Cemented from 0 to 869 ","feet. Pump set at 230 feet. " 4053504,4,"Aquifer test data in TWDB files. ", 4053506,1,"Owner's Cedar Ridge Park #2 well. ","Measured yield 10 GPM with 7 feet " 4053506,2,"drawdown after pumping 24 hours in ","1966. Specific capacity 1.4 GPM/ft." 4053506,3,"Cemented from 0 to 1068 feet. Pump ","set at 210 feet. Geophysical log " 4053506,4,"Q-25. ", 4053601,1,"Measured yield 30 GPM in 1970. ","Cemented from 0 to 975 feet. " 4053701,1,"Historical observation well. ", 4053702,1,"Historical observation well. ", 4053703,1,"Owner's Temple Lake Park #1. ","Measured yield 10 GPM with 4 feet " 4053703,2,"drawdown after pumping 24 hours in ","1961. Specific capacity 2.5 GPM/ft." 4053703,3,"Cemented from 0 to 959 feet. ","Unused public supply well. " 4053703,4,"Aquifer test data in TWDB files. ", 4053704,1,"Historical observation well. ","Well was originally drilled to 875 " 4053704,2,"ft by another driller; J.L. Myers ","Sons drilled to 1081 ft. " 4053705,1,"Owner's Rogers Park #1 well. Unused","public supply well. Reported yield " 4053705,2,"11.25 GPM with 45 feet drawdown ","after pumping 24 hours in 1961. " 4053705,3,"Specific capacity 0.25 GPM/ft. ","Cemented from 0 to 959 feet. Pump " 4053705,4,"set at 180 feet. Aquifer test data ","in TWDB files. " 4053706,1,"Owner's Roger's Park #2 well. ","Unused public supply well. " 4053901,1,"Owner's Temple Airport #1 well. ","Unused public supply well. " 4053901,2,"Measured yield 250 GPM in 1942. ","Cemented from 0 to 1010 feet. " 4053902,1,"Owner's #2 well. Destroyed public ","supply well. Historical observation" 4053902,2,"well. Cemented from 0 to 1210 feet.", 4054401,1,"Owner's #1 well. Cemented from 0 to","1657 feet. Geophysical log Q-22. " 4054501,1,"Owners well #1. Aquifer test data ","in TWDB R-98. Measured yield 170 " 4054501,2,"GPM with 33 feet drawdown after ","pumping 9 hours in 1965. Specific " 4054501,3,"capacity 5.15 GPM/ft. Plugged PS ","well. Historical observation well. " 4054501,4,"Aquifer test results in TWDB R-98, ","R-195 and R-326. Test data in TWDB " 4054501,5,"files. ", 4054502,1,"Standby Well. Historical ","observation well. Measured yield " 4054502,2,"170 GPM with 40 feet drawdown after","pumping 36 hours in 1978. Specific " 4054502,3," capacity 4.25 GPM/ft. Cemented ","from 0 to 1692. Pump set at 610 " 4054502,4,"feet. Aquifer test data in TWDB ","files. " 4054503,1,"Owners well #2. Measured yield 375 ","GPM with 109 feet drawdown in 1970." 4054503,2,"Specific capacity 3.44 GPM/ft. Ce- ","mented from 0 to 1600 feet. Pump " 4054503,3,"set at 550 feet. Geophysical log ","Q-17. PWS ID " 4054503,4,"#0140037A. ", 4054701,1,"Owner's #1 well. Unused public ","supply well. Measured yield 200 GPM" 4054701,2,"with 60 feet drawdown after pumping","30 hours in 1968. Specific " 4054701,3,"capacity 3.33 GPM/ft. Cemented from","0 to 1600 feet. Pump set at 400 " 4054701,4,"feet. ", 4054801,1,"Owner's #1 well. Measured yield 120","GPM with 13 feet drawdown after " 4054801,2,"pumping 30 hours in 1969. Specific ","capacity 9.2 GPM/ft. Cemented from " 4054801,3,"0 to 1710 feet. Pump set at 462 ","feet. " 4055701,1,"Owners well #1. Reported yield 100 ","GPM. Cemented from 0 to 2519 feet. " 4055701,2,"Pump set at 200 feet. Geophysical ","log Q-21. Historical observation " 4055701,3,"well. ", 4057601,1,"Annular Seal from 362' to 346', ","346' to 10', 10' to 0'. " 4057601,2,"Neoprene Packer at 366', 364', 362'",". Well in fenced area. " 4057601,3,"Transducer, Stevens ", 4057602,1,"Annular Seal from 489' to 464', ","464' to 10', 10' to 0'. " 4057602,2,"Neoprene Packer at 495', 492', 489'",". " 4057602,3,"Transducer, Stevens ", 4057902,1,"GCD well #E-02-721G. ", 4057903,1,"GCD well #E-02-722G. ", 4058201,1,"Annular Seal from 450' to 435', ","91' to 10', 10' to 0'. " 4058201,2,"Neoprene Packers at 95', 93', 91'. ","Burlap Packer at 92'. " 4058201,3,"Transducer, Sutron. ", 4058701,1,"TCEQ's user #0140159. ", 4058801,1,"Measured yield 20 GPM. Pump set at ","294 feet. " 4058802,1,"Measured yield 7 GPM. Pump set at ","252 feet. " 4058902,1,"Clearwater GCD no longer measuring.","Historical observation well. " 4058903,1,"GCD well #E-06-063P. ", 4059101,1,"Abandoned public supply well. ","Reported yield 75 GPM. " 4059102,1,"Owner's #2 well. Abandoned public ","supply well. Measured yield 35 GPM " 4059102,2,"with 377 feet drawdown in 1941. ","Specific capacity 0.09 GPM/ft. " 4059102,3,"Geophysical log Q-12. Logged to 498","feet. " 4059102,4,"Aquifer test results in TWDB R-195,","data in TWDB files. " 4059104,1,"PWS ID#0140172. ", 4059701,1,"Measured yield 10 GPM with 0 feet ","drawdown after pumping 10 hours in " 4059701,2,"1963. Cemented from 0 to 32 feet. ","Pump set at 280 feet. " 4059701,3,"Historical observation well. ", 4059801,1,"Geophysical log Q-10. ", 4059802,1,"GCD well #E-02-804G. ", 4059901,1,"Geophysical log Q-7. ", 4060101,1,"Jetted yield 150 GPM. ", 4060301,1,"Historical observation well. ", 4060302,1,"Owner's West Cliff Park #1 well. ","Measured yield 11 GPM with 3 feet " 4060302,2,"drawdown after pumping 24 hours in ","1961. Specific capacity 3.67 GPM/ft" 4060302,3,"Cemented from 0 to 912 feet. Pump ","set at 140 feet. Aquifer test data " 4060302,4,"in TWDB files. ", 4060402,1,"Depth to pump bowl is 500 ft. ","Shale packer at 680 ft. " 4060402,2,"Cement packer at 40 ft. ", 4060501,1,"Owner's #1 well. Unused public ","supply well. Measured yield 100 GPM" 4060501,2,"with 74 feet drawdown after pumping","10 hours in 1966. Specific capacity" 4060501,3,"1.37 GPM/ft. Cemented from 0 to ","1145 feet. Originally drilled to " 4060501,4,"1152 and plugged back to 979 feet. ","Aquifer test data in TWDB files. " 4060502,1,"Measured yield 20 GPM in 1971. ","Cemented from 0 to 850 feet. " 4060601,1,"Owner's Yarrell #2. Measured yield ","213 GPM with 176 feet drawdown in " 4060601,2,"Oct. 3,1942. Plugged and abandoned.","Aquifer test data in TWDB R-98. " 4060601,3,"Specific capacity 1.2 GPM/ft. No ","test data in TWDB files. " 4060701,1,"Cemented from 0 to 825 feet. ","Abandoned. Well will be covered by " 4060701,2,"Still House Reservoir. ", 4060801,1,"Owner's Copeland #1 well. Measured ","yield 390 GPM with 105 feet draw- " 4060801,2,"down after pumping 1 hour in 1942. ","Specific capacity 3.7 GPM/ft. " 4060801,3,"Abandoned. Aquifer test data in ","TWDB R-98, 195 and 326. No test " 4060801,4,"data in TWDB files. ", 4060901,1,"Owner's Bloomer #1 well. Measured ","yield 500 GPM with 91 feet draw- " 4060901,2,"down after pumping 24 hours in 1942","Specific capacity 5.5 GPM/ft. " 4060901,3,"Cemented from 0 to 921 feet. ","Abandoned. " 4060901,4,"Aquifer test results in TWDB R-195 ","and 326. No test data in TWDB file." 4060902,1,"Owner's Wilson #2 well. Measured ","yield 350 GPM with 116 feet " 4060902,2,"drawdown after pumping 24 hours in ","1942. Specific capacity 3.0 GPM/ft." 4060902,3,"Abandoned public supply well. ","Aquifer test data in TWDB R-98. " 4060902,4,"No test data in TWDB files. ", 4060903,1,"Owner's Safley #1 well. Measured ","yield 420 GPM with 85 feet draw- " 4060903,2,"down after pumping 24 hours in ","1941. Specific capacity 5.0 GPM/ft." 4060903,3,"Cemented from 0 to 684 feet. ","Aquifer test data in TWDB R-98. " 4060903,4,"Abandoned public supply well. No ","aquifer test data in TWDB files. " 4060904,1,"Owner's Wilson #1 well. Measured ","yield 440 GPM with 103 feet draw- " 4060904,2,"down after pumping 24 hours in ","1941. Specific capacity 4.3 GPM/ft." 4060904,3,"Cemented from 0 to 755 feet. ","Aquifer test data in TWDB R-98. " 4060904,4,"Abandoned public supply well. ", 4060905,1,"Owner's Yarrell #1 well. Measured ","yield 520 GPM with 153 feet draw- " 4060905,2,"down after pumping 10 hours in ","1942. Specific capacity 3.4 GPM/ft." 4060905,3,"Aquifer test data in TWDB R-98. ","Abandoned public supply well. " 4060907,1,"Owner's Stillhouse Hollow Dam well.","Measured yield 13 GPM with 6 feet " 4060907,2,"drawdown after pumping 24 hours in ","1966. Specific capacity 2.17 GPM/ft" 4060907,3,"Unused public supply well. ","Historical observation well. " 4060908,1,"Cemented from 0 to 970 feet. ", 4060912,1,"Tahuaya Spring. Spring is boxed-in ","for public supply use. Field cond- " 4060912,2,"uctance 643 in 2003. ", 4061101,1,"Owner's Headquarters well. Measured","yield 150 GPM with 35 feet draw- " 4061101,2,"down after pumping 24 hours in ","1949. Specific capacity 4.3 GPM/ft." 4061101,3,"Pump set at 250 feet. ","Geophsical log Q-8. " 4061102,1,"Historical observation well. ", 4061103,1,"Flows. ", 4061104,1,"Historical observation well. ", 4061105,1,"Owner's Live Oak Ridge #1 well. ","Measured yield 11.5 GPM with 3 feet" 4061105,2,"drawdown after pumping 24 hours in ","1961. Specific capacity 4 GPM/ft. " 4061105,3,"Cemented from 0 to 1035 feet. ","Pump set at 200 feet. " 4061106,1,"Owner's Temple Lake Park #2 well. ", 4061107,1,"Unused public supply well. Cemented","from 0 to 1046 feet. Pump set at " 4061107,2,"357 ft. ", 4061201,1,"Historical observation well. ", 4061301,1,"Temp. 80 degrees F. ", 4061401,1,"Owner's #2 well. Unused public ","supply well. Reported yield 1000 " 4061401,2,"GPM. Cemented from 0 to 390 feet. ","Pump set at 200 feet. " 4061401,3,"Geophysical log Q-6. ", 4061402,1,"Owner's #1 well. Measured yield 350","GPM with 64 feet drawdown after " 4061402,2,"pumping 2.75 hours. Specific ","capacity 5.4 GPM/ft. " 4061402,3,"Aquifer test data in TWDB R-98. ","Test data in TWDB files. " 4061402,4,"Unused public supply well. ", 4061403,1,"Reported yield 320 gpm in 1942. ","Well was originally drillin in 1903" 4061403,2,"and later reworked to 1172 ft. ","Abandoned public supply well. " 4061403,3,"Aquifer test data in TWDB R-98. ","Test data in TWDB files. " 4061404,1,"Historical observation well. Unused","public supply well. " 4061405,1,"Historical observation well. Unused","public supply well. " 4061501,1,"Owner's City #4 well. Reported ","yield 600 GPM. Cemented fro 0 to " 4061501,2,"708 feet. Pump set at 406 feet. ","Unused public supply well. " 4061502,1,"Measured yield 355 GPM with 112 ","feet drawdown after pumping 12 " 4061502,2,"hours in 1948. Specific capacity ","3.17 GPM/ft. Pump set at 390 feet. " 4061503,1,"Owner's #1 well. Reported yield 100","GPM in 1959. Cemented from to 1140 " 4061503,2,"feet. Pump set at 200 feet. ","Geophysical log Q-19. " 4061504,1,"Owner's #2 well. Cemented from 0 to","1137 feet. Pump set at 200 feet. " 4061505,1,"Flows 100 gpm in 1941, 11 gpm in ","1960. Unused recreational well. " 4061506,1,"Plugged and abandoned. ", 4061507,1,"Owner's City #1 well. Measured ","yield 508 GPM with 199 feet draw- " 4061507,2,"down in 1951. Specific capacity ","2.55 GPM/ft. Cemented from 0 to " 4061507,3,"1140 feet. Pump set at 410 feet. ","Geophysical log Q-4. Unused public " 4061507,4,"supply well. ", 4061508,1,"Owner's City #2 well. Cemented from","0 to 1196 feet. Unused public " 4061508,2,"supply well. ", 4061509,1,"Owner's City #3 well. Measured ","yield 798 GPM with 362 feet draw- " 4061509,2,"down in 1951. Specific capacity ","2.19 GPM/ft. Cemented from 0 to " 4061509,3,"1155 feet. Historical observation ","well. " 4061510,1,"Reported yield 1000 GPM. Cemented ","from to 400 feet. Pump set at 300 " 4061510,2,"feet. ", 4061601,1,"Measured yield 250 GPM with 110 ","feet drawdown in 1955. Specific " 4061601,2,"capacity 2.27 GPM/ft. Cemented ","from 0 to 1685 feet. " 4061703,1,"Owner's City #3 well. Measured ","yield 650 GPM with 330 feet draw- " 4061703,2,"down after pumping 12 hours in ","1952. Specific capacity 1.97 GPM/ft" 4061703,3,"Cemented from 0 to 1204 feet. Pump ","set at 575 feet. Historical " 4061703,4,"observation well. Unused public ","supply well. " 4061705,1,"Test well. Field verified well ","destroyed in Oct. 2009. " 4061901,1,"Measured yield 75 GPM with 47 feet ","drawdown in 1964. Specific capacity" 4061901,2,"1.6 GPM/ft. Geophysical log Q-18. ","Plugged PS well in 2002. Historical" 4061901,3,"water level recorder observation ","well. " 4062101,1,"Owner's City #4 well. Reported ","yield 1000 GPM. Cemented from 0 to " 4062101,2,"1846 feet. Unused public supply. ","Historical observation well. " 4062101,3,"Geophysical log Q-23. ", 4062102,1,"Owner's #1 well. Measured yield 510","GPM with 136 feet drawdown after " 4062102,2,"pumping 4 hours in 1965. Specific ","capacity 3.75 GPM/ft. " 4062401,1,"Owner's McCloskey Army Hs #1 ","Measured yield 500 GPM with 32 feet" 4062401,2,"drawdown in 1944. Specific ","capacity 15.6 GPM/ft. " 4062401,3,"Aquifer test data in TWDB R-98. ","Geophysical log Q-1. " 4062401,4,"Aquifer test data in TWDB files. ", 4062501,1,"Measured yield 100 GPM with 46 ","feet drawdown after pumping 36 " 4062501,2,"hours in 1966. Specific capacity ","2.17 GPM/ft. Cemented from 0 to " 4062501,3,"2236 feet. Pump set at 300 feet. ", 4062801,1,"Owners well #1. Reported flowed 100","GPM in 1960. Cemented from 0 to " 4062801,2,"2203 feet. Historical observation ","well. " 4063501,1,"Owner's #1 well. ","GCD well#N-02-034G. " 4063801,1,"Geophysical log Q-16. ", 5802102,1,"Geophysical log Q-14. ", 5802301,1,"Plugged and abandoned. ", 5802502,1,"Owner's #2 well. Estimated yield ","25 GPM. " 5802503,1,"Reported yield 11 GPM with 102 feet","drawdown after pumping 24 hours in " 5802503,2,"2004. Specific capacity 0.10 GPM/- ","ft. Test results from consultant in" 5802503,3,"TWDB files. ", 5803301,1,"Reported yield 5 GPM. Pump set at ","160 feet. " 5803402,1,"Historical observation well. ","Clearwater GCD no longer measures. " 5803402,2,"Broken airline owners not replacing", 5803502,1,"Measured flow .5 gpm on May 19,1981","Flowing on 6/4/02. " 5803503,1,"Aquifer code is uncertain. ","(RB 1/12/2011). " 5803503,2,"Bailer yield: 50 gpm with 150 ft. ","drawdown after 3 hours in 1997. " 5803503,3,"Gravel packed from 100 to 614 ft. ", 5803601,1,"Willingham Place Spring #1. ","Estimated flow <.5. " 5803602,1,"Estimated flow 3 gpm on May 20,1981","Willingham Place Spring #2. " 5803603,1,"Estimated flow 2 gpm on May 21,1981","Willingham Place Spring #3. " 5803801,1,"Historical observation well. ", 5803804,1,"Historical observation well. ","Estimated yield 50 GPM in 1981. " 5803804,2,"Cemented from 0 to 18 feet. Pump ","set at 504 feet. " 5803805,1,"Historical observation well. ", 5803901,1,"Historical observation well. Pump ","set at 261 feet. " 5803902,1,"Reported yield 3 GPM in1970. ", 5803903,1,"Measured flow 80 GPM on 5/21/81. ","Field conductance 569 in 2003. " 5803903,2,"""Headquarters"" spring. Fied cond- ","uctance 510 in 2008. " 5803904,1,"Measured flow 35 gpm on May 19,1981",". " 5803905,1,"Measured flow 24 gpm May 18, 1981. ", 5803906,1,"Measured flow 22 gpm May 18,1981. ", 5803907,1,"Measured flow 10 gpm May 18,1981. ", 5803908,1,"Measured flow 36 gpm Aug.14,1981. ", 5803909,1,"Measured flow 197 gpm, Aug.14,1981.", 5803910,1,"Measured flow 5 gpm on Aug.14,1981.", 5803911,1,"Measured flow 193 gpm Aug.12,1981. ", 5804103,1,"Reported yield 8 GPM in 1992. ", 5804104,1,"Depth to pump bowl is 500 ft. ","Cement packers at 40 and 640 ft. " 5804201,1,"Owner's Indian Camp Spring. ","Measured flow 170 GPM May 19,1981. " 5804202,1,"Reported yield 5 gpm. ", 5804301,1,"Reported yield 30 GPM in 1974. ", 5804302,1,"Reported yield 2 GPM in 1973. ", 5804302,2,"Historical recorder well. ", 5804303,1,"Reported yield 1.5 GPM in 1973. ", 5804304,1,"Reported yield 2 GPM in 1974. ", 5804305,1,"Reported yield 8 GPM in 1974. ", 5804306,1,"Reported yield 5 GPM in 1977. ", 5804307,1,"Reported yield 12 GPM in 1970. ", 5804308,1,"Measured yield 12 GPM in 1970. ", 5804309,1,"Reported yield 7 GPM in 1970. ", 5804310,1,"Reported yield 8 GPM in 1972. ", 5804311,1,"Test hole AX-18. Unable to locate ","well in Oct. 2009. " 5804312,1,"Reported yield 15 GPM with 9 feet ","drawdown after pumping 36 hours in " 5804312,2,"2004. Specific capacity 1.6 GPM/ft.","Test data from consultant. " 5804401,1,"Measured flow .5 gpm May 20,1981. ","Willingham Church Spring. " 5804402,1,"Measured flow 18 gpm May 20,1981. ","Hodge Place Spring. " 5804403,1,"Estimated flow 4 gpm on May 19,1981","Holmes Spring. " 5804404,1,"Measured spring flow 54 GPM in 1981", 5804405,1,"Depth to pump bowl is 500 ft. ","Cement packer at 790 ft. " 5804406,1,"Reported yield 30 GPM with 36 feet ","drawdown after pumping 26 houra in " 5804406,2,"2001. Specific capacity 0.8 GPM/ft.","Data from consultant. " 5804501,1,"Robertson Springs. Two springs ","about 30 yards apart. Field cond. " 5804501,2,"636 in 2003. 2a and 2b in Brune's ","""Springs of Texas"". " 5804501,3,"Sampled segment 2a 3/23/2010. ", 5804501,4,"Spring 2b is SWN: 58-04-515. ","Elev. from Goggle Earth. " 5804502,1,"Perforated from 65 to 85 feet. ", 5804503,1,"Reported yield 4 GPM. ", 5804504,1,"Reported yield 12 GPM in 1974. ", 5804505,1,"Reported yield 250 GPM. ", 5804507,1,"Reported yield 10 GPM. ", 5804508,1,"Reported yield 350 GPM. Cemented ","from 0 to 50 feet. Pump set at 92 " 5804508,2,"feet. Owner's #3 well. ", 5804509,1,"Owners well #5. Reported yield 380 ","GPM with 5 feet drawdown after " 5804509,2,"pumping 40 hours in 1990. Specific ","capacity 76 GPM/ft. Cemented from " 5804509,3,"10 feet. ", 5804510,1,"Estimated yield 100 GPM. Pump set ","at 120 feet. Cemented from 0 to 110" 5804510,2,"feet. Reported yield 350 GPM with ","15 feet drawdown after pumping 70 " 5804510,3,"hours in 1997. Specific capacity ","23 GPM/ft. Cemented from 0 to 110 " 5804510,4,"feet. Pump set at 120 feet. ", 5804512,1,"Owner's Wel #8. Measured yield 604 ","GPM with 18 feet drawdown after " 5804512,2,"pumping 72 hours in 2000. Specific ","capacity 33.56 GPM/ft. Cemented " 5804512,3,"from 0 to 100 feet. Owner's #8 well", 5804513,1,"Owner's Well #9. Measured yield 205","GPM with 36 feet drawdown after " 5804513,2,"pumping 72 hours in 2000. Specific ","capacity 5.69 GPM/ft. Cemented from" 5804513,3,"0 to 100 feet. ", 5804514,1,"Reported yield 30 GPM with 28 feet ","drawdown after pumping 24 hours in " 5804514,2,"2001. Specific capacity 1.07 GPM/ ","ft. Data from consultant. " 5804515,1,"Elev. from Goggle Earth. ", 5804515,2,"Segment 2b is east of 2a. ", 5804601,1,"Historical observation well. ", 5804602,1,"Reported yield 130 GPM with 65 feet","drawdown after pumping 24 hours in " 5804602,2,"1968. Specific capacity 2.0 GPM/ft.","Owner's #1 well. Cemented from 0 to" 5804602,3,"42 feet. Geophysical log Q-24. ", 5804603,1,"Owner's #2 well. Unused public ","supply well. " 5804604,1,"Measured yield of 125 GPM with 3 ","feet drawdown after pumping 24 " 5804604,2,"hours in 1972. Specific capacity ","41.6 GPM/ft. Owners well #2. " 5804604,3,"Cemented from 0 to 75 feet. Pump ","set at 84 feet. " 5804605,1,"Measured yield 10 GPM with 15 feet ","drawdown after pumping .5 hour in " 5804605,2,"1969. Specific capacity 0.67 GPM/ft", 5804606,1,"Measured yield 10 GPM with 34 feet ","drawdown after pumping 0.50 hour " 5804606,2,"in 1971. Specific capacity 0.29 ","GPM/ft. " 5804607,1,"Cemented from 0 to 20 feet. ", 5804609,1,"Reported yield 10 GPM. ", 5804610,1,"Measured yield 30 GPM with 60 feet ","drawdown after pumping 1 hour in " 5804610,2,"1974. Specific capacity 0.5 GPM/ft.","Cemented from 0 to 35 feet. " 5804611,1,"Measured yield 25 GPM with 15 feet ","drawdown after pumping 0.5 hour in " 5804611,2,"1971. Specific capacity 1.67 ","GPM/ft. " 5804612,1,"Measured yield 8 GPM. ", 5804613,1,"Known as Big Boiling Spring. ","Measured flow 1,497 gpm on May 15, " 5804613,2,"1981. ", 5804614,1,"Owner's Spring Groves Spring. ","Measured flow 1219 GPM on May 15, " 5804614,2,"1981. ", 5804615,1,"Measured yield 30 GPM with 15 feet ","drawdown after pumping 0.5 hour in " 5804615,2,"1971. Specific capacity 2 GPM/ft. ", 5804616,1,"Measured yield 30 GPM with 20 feet ","drawdown after pumping 0.5 hour in " 5804616,2,"1971. Specific capacity 1.5 GPM/ft.", 5804617,1,"Measured yield 6 GPM with 30 feet ","drawdown after pumping 0.5 hour. " 5804617,2,"Specific capacity 0.2 GPM/ft. ", 5804618,1,"Measured yield 40 GPM in 1970. ","Cemented from 0 to 23 feet. " 5804619,1,"Measured yield 25 GPM with 118 feet","drawdown after pumping 3.5 hours in" 5804619,2,"1970. Specific capacity 0.21 GPM/ft","Pump set at 90 feet. " 5804620,1,"Test hole. Former TWDB recorder ","well. " 5804621,1,"Casing cemented from 147 feet to ","land surface. Reported yield " 5804621,2,"350 gpm. Well #4. Reported yield ","395 GPM with 88 feet drawdown after" 5804621,3,"pumping 2:40 hours in 1983. ","Specific capacity 4.5 GPM/ft. " 5804622,1,"Reported yield 325 GPM. ", 5804623,1,"Reported yield 101 GPM with 49 feet","drawdown after pumping 36 hours in " 5804623,2,"1992. Specific capacity 2.06 GPM/ft","Owner's Hill well. Cemented from 0 " 5804623,3,"101 feet. ", 5804624,1,"mineral well used for hot tub ", 5804625,1,"old feed store well ", 5804626,1,"Owner's Well #7. Measured yield 400","GPM with 30 feet drawdown after " 5804626,2,"pumping 76 hours in 1999. Specific ","capacity 13.3 GPM/ft. Pump set at " 5804626,3,"120 feet. Cemented from 0 to 105 ","feet. " 5804628,1,"Borehole camera survey on 8/5/2011.","Float & weight, Stevens GS. " 5804629,1,"Elev. From Goggle Earth. ", 5804701,1,"Measured yield 3 GPM with 380 feet ","drawdown after pumping 0.5 hour in " 5804701,2,"1976. Specific capacity 0.008 ","GPM/ft. Not potable. " 5804702,1,"Test hole AX-17. ", 5804702,2,"Transducer, Sutron. ", 5804703,1,"Measured flow 45 gpm on May 21,1981",". " 5804802,1,"Reported yield 50 gpm. ", 5804803,1,"Reported yield 50 gpm. Cemented ","from 0 to 106 feet. " 5804804,1,"Reported yield 2 GPM. Cemented from","0 to 20 feet. " 5804805,1,"Reported yield 10 GPM. ", 5804806,1,"Measured yield 15 GPM with 30 feet ","drawdown after pumping 2 hours in " 5804806,2,"1974. Specific capacity 0.5 GPM/ft.","Cemented from 0 to 20 feet. " 5804807,1,"Reported yield 15 gpm. ", 5804808,1,"Measured yield 170 GPM with 2 feet ","drawdown in 1974. Specific capacity" 5804808,2,"85 GPM/ft. Cemented from 0 to 225 ","feet. Pump set at 270 feet. " 5804808,3,"Owner's #2 well. ", 5804809,1,"Measured yield 5 GPM with 150 feet ","drawdown after pumping 1 hour in " 5804809,2,"1969. Specific capacity 0.03 GPM/ft", 5804810,1,"Test well #3. ", 5804811,1,"Well #5. Reported yield 225 GPM ","with 30 feet drawdown after pumping" 5804811,2,"36 hours in 1990. Specific capacity","7.5 GPM/ft. Cemented from o to 160 " 5804811,3,"feet. ", 5804816,1,"Older domestic well reworked by ","Texdot for rest area construction. " 5804816,2,"Float & weight, Stevens GS. ", 5805102,1,"Bailed 2 GPM with 142 feet drawdown","after 0.5 hour. Specific capacity " 5805102,2,"0.01 GPM/ft. ", 5805103,1,"Bailed 15 GPM in 1971. ", 5805104,1,"Reported yield 17 GPM with 27 feet ","drawdown after pumping 72 hours in " 5805104,2,"2003. Specific capacity 0.62 GPM/- ","ft. Data from consultant report. " 5805105,1,"Reported yield 17 GPM with 14 feet ","drawdown after pumping 72 hours in " 5805105,2,"2003. Specific capacity 1.2 GPM/- ","ft. Test data from consultant . " 5805201,1,"Historical observation well. ", 5805202,1,"Historical observation well. ","Measured yield 225 GPM with 87 feet" 5805202,2,"drawdown after pumping 24 hours in ","1968. Specific capacity 2.6 GPM/ft." 5805202,3,"Cemented from 0 to 1706 feet. Pump ","set at 210 feet. " 5805203,1,"Reported flow 80 GPM in 1967. ","Cemented fro 0 to 4 feet. " 5805204,1,"Measured yield 6 GPM with 100 feet ","drawdown after pumping 1 hour in " 5805204,2,"1972. Specific capacity 0.06 GPM/ft", 5805401,1,"Pump set at 126 feet. ", 5805402,1,"Originally drilled as oil test. ", 5805403,1,"Observation well. Estimated yield ","15 GPM. Cemented from 0 to 1590 " 5805403,2,"feet. Pump set at 240 feet. ", 5805501,1,"Reported yield 8 GPM. ", 5805701,1,"Reported yield 25 GPM with 40 feet ","drawdown after pumping 3 hours in " 5805701,2,"1983. Specific capacity 0.62 GPM/ft",". " 5805901,1,"Owner's #1 well. Observation well. ","Measured yield 83 GPM with 151 feet" 5805901,2,"drawdown in 1943. Specific capacity","0.54 GPM/ft. Flowed 63 GPM in 1943." 5805901,3,"Flowed 10.6 GPM in 1965. Pump set ","at 250 feet. " 5805902,1,"Historical observation well. ","Estimated yield 135 GPM. Pump set " 5805902,2,"330 feet. Geophysical log Q-20. ", 5806101,1,"Estimated yield 300+ GPM. ", 5806102,1,"Owner's Little River well. ","Reported flowed 103 gpm in 1964. " 5806102,2,"Reported flow 125 gpm in 1961. ","Historical observation well. " 5806301,1,"Pump yield: 750 gpm with 30 ft. ","drawdown after 36 hours in 2011. " 5806301,2,"Aquifer code provided by GCD. ","Depth to pump bowl is 1010 ft. " 5806301,3,"Gravel packed from 2750 to 3247 ft.", 5806601,1,"Measured yield 300 GPM with 130 ","feet drawdown after pumping 24 " 5806601,2,"hours in 1971. Specific capacity ","2.3 GPM/ft. Cemented from 0 to 2996" 5806601,3,"feet. Pump set at 340 feet. ", 5807301,1,"Historical observation well. Flows.", 5807401,1,"Geophysical log Q-11. ", 5807701,1,"Owners well #1. Reported to have ","flowed 800 GPM in 1940 and 180 GPM " 5807701,2,"in 1965. Plugged PS well 12/12/05. ", 5813301,1,"TWDB test hole. Geophysical log. ","Unable to locate well in Oct. 2009." 5813504,1,"Well flows. ", 5814401,1,"Geophysical log Q-9. ", 5814402,1,"Owners well #2 or Bartlett well. ","PWS ID #0140007B. " 5814802,1,"Geophysical log Q-15. ",